Fastwarm® technical information
Comparison of popular construction boards
| Properties | Marmox | Wedi | Aquapanel Thermal | Fastwarm® |
| Thermal Conductivity (W/mK) | 0.027 | 0.033 | 0.027 | 0.027 |
| Compressive Strength (kPa) | 300 | 250 | 220 | 300 |
| Water Absorption (Capillarity) | Nil | Nil | Nil | Nil |
Comparison of popular thermal insulation boards
| Properties | Celotex GA3000Z | Kingspan TF70 | FloorTherm | Fastwarm® |
| Thermal Conductivity (W/mK) | 0.023 | 0.023 | 0.023 | 0.027 |
| Compressive Strength (kPa) | 120 | 140 | 150 | 300 |
| Water Absorption (Capillarity) | Nil | Nil | Nil | Nil |
Technical data for different depths
| Fastwarm® Board Sizes | Thermal Conductivity (W/mK) | Resistance (k-value) | U-value (W/m²K) | Compressive Strength (kPa) | Weight (kgs) |
| 90 days @ 10 °C |
|
| 1 kPa = 1 kg/cm² | 30 kgs/m³ |
| 1220 x 600 x 6 mm | 0.027 | 0.22 | 4.50 | 300 | 0.13 |
| 1220 x 600 x 10 mm | 0.027 | 0.37 | 2.70 | 300 | 0.22 |
| 1250 x 600 x 20 mm | 0.029 | 0.69 | 1.45 | 280 | 0.45 |
| 1250 x 600 x 30 mm | 0.029 | 1.03 | 0.97 | 280 | 0.68 |
| 1250 x 600 x 40 mm | 0.029 | 1.38 | 0.72 | 280 | 0.90 |
| 1250 x 600 x 50 mm | 0.029 | 1.72 | 0.58 | 280 | 1.13 |
| 1250 x 600 x 60 mm | 0.029 | 2.07 | 0.48 | 280 | 1.35 |
| Standard | ISO 8301/BS EN 12667 |
|
| BS EN 826 |
|
Thermal energy moves from a higher temperature to a lower one, the bigger the difference the faster the transfer.
| Thermal Conductivity | Measure of the rate at which material will pass heat energy, expressed in units of watts per square metre per degree Celsius of temperature difference (W/mK). |
| Resistance | Each type of material has it's own particular rate of thermal conductivity affecting the speed of thermal transfer (k-value) |
| U Value | Measure of how much heat energy will pass through a square metre of structure when air temperatures on either side differ by one degree Celsius. The fabric of any building will typically consists of a number of components each with their characteristic resistance value, the U-value is a combination of all these values. U-values are expressed in units of watts per square metre per degree of temperature difference (W/m²K) |
Fastwarm® technical data sheet
| Properties | Standard | Unit | Data |
| Density | EN 1602 | Kg/m² | 28 |
| Thermal conductivity, 90 days, 10°C | ISO 8301 | W/mK | 0.027 |
| Compressive strength at 10% deflection or yield, (vertical) | EN 826 | kPa | 300 |
| Compressive modulus | EN 826 | kN/m² | 12-20,000 |
| Tensile strength | EN 1607 | kPa | 500 |
| Tensile modulus | EN 1607 | kPa | 12-20,000 |
| Shear strength | EN 1209 | kPa | 250 |
| Shear modulus | EN 1209 | kPa | 8,000 |
| Design compressive stress, <2% compression | EN 1606 | kN/m² | 110 |
| Water vapour resistivity | EN 12086 | (Uu)- value | 100-160 |
| Water absorption by immersion (28 days, full boards) | DIN 53434 | Vol-% | 0.5 |
| Capillarity | - | nil | nil |
| Coefficient of linear thermal expansion | BS 3837: Method 13 | mm/mK | 0.07 |
| Temperature limits | - | °C | -50/+75 |
| Fire classification | Bs 3837: Pt2: 1990 | - | - |
| Edge profile | - | - | butt |
| Surface finish | - | - | planed |